DSC NEO Trouble Conditions





[01] Bell Circuit Trouble: The bell circuit is open. 
[02] RF Jam: The HSM2HOSTx has detected an RF Jam condition. 
[03] Aux Supply Trouble: The alarm controller, HSM2204 or HSM2300 has an overcurrent condition on Aux. 
[04] Loss of Clock: System time and date require programming. 
[05] Output 1 Fault: An HSM2204 module has detected an open condition on output #1. 
[01] Panel Low Battery Trouble: The battery voltage (under load) is below 11.5V. Restores at 12.5V. 
[02] Panel No Battery: No battery connected to alarm controller.
[04] HSM2204 01 – 04 Low Battery: An HSM2204 has a battery voltage less than 11.5V. 
[05] HSM2204 01 – 04 No Battery: No battery connected to HSM2204. 
[07] HSM2300 01 – 04 Low Battery: An HSM2300 has a battery voltage less than 11.5V 
[08] HSM2300 01 – 04 No Battery: No battery connected to HSM2300.

[01] HSM2HOSTx Bus Low Voltage: The HSM2HOSTx module has measured less than 6.3V on its Aux input.
[02] Keypad 01 – 16 Bus Low Voltage: A hardwired keypad has a bus voltage of less than 6.9V for ICON/LCD (RF version) and 7.7V for non-RF models. 
[04] HSM2108 01 – 15 Bus Low Voltage: A zone expander has a bus voltage of less than 5.9V. 
[05] HSM2300 01 – 04 Bus Low Voltage: A power supply has a bus voltage of less than 6.9V. 
[06] HSM2204 01 – 04 Bus Low Voltage: A high current output module has a bus voltage of less than 6.9V. 
[08] HSM2208 01 – 16 Bus Low Voltage: The low current output module has detected a voltage less than 5.9V on its aux input. 
[09] HSM2955 Bus Low Voltage: The audio module has detected a voltage less than 9.65V on its aux input

[01] Zone 001 – 128 AC Trouble: An AC trouble has been detected on a PGX934 PIR + Camera. 
[03] Siren 01 – 16 AC: A siren has an AC trouble. 
[04] Repeater 01 – 08 AC: A wireless repeater has an AC trouble. 
[05] HSM2300 01 – 04 AC: An HSM2300 has an AC trouble. 
[06] HSM2204 01 – 04 AC: An HSM2204 has an AC trouble. 
[07] Panel AC: The alarm controller has an AC failure condition

[01] Zone 001 – 128: A zone is in fault. Additional information displayed on LCD keypads for the following troubles: Fire Trouble (2-W Smoke, PGX916, PGX926), Freeze (PGX905), Self Test (PGX984), CO (PGX913), and Probe Disconnected (PGX905). Also generated by a short on hardwired zones when DEOL is used or by a wireless supervisory fault. 
[02] Keypad 01 – 16: A wireless or hardwired keypad is in fault. 
[03] Siren 01 – 16: A siren is in fault. 
[04] Repeater 01 – 08: A wireless repeater is in fault (supervisory or loss of AC/DC).

[01] Zone 001- 128: Wireless zone has a low battery. 
[02] Keypad 01-16: Keypad has a low battery. 
[03] Siren 01 – 16: Siren has a low battery. 
[04] Repeater 01 – 08: Repeater has a low battery. 
[05] User 01 – 1000: Wireless Key has a low battery. 

[01] Zone 001 – 128 Tamper: A wireless or hardwired zone configured for DEOL operation is in tamper. 
[02] Keypad 01 – 16 Tamper: A hardwired or wireless keypad is in tamper.
[03] Siren 01 – 16 Tamper: A wireless siren is in tamper. 
[04] Repeater 01 – 08 Tamper: A wireless repeater is in tamper. 
[05] Audio Station 01 – 04 Tamper: An audio station connected to an HSM2955 is in tamper.

[01] Zone 001 – 128 RF Delinquency: No response from a wireless zone for 13 minutes. This trouble prevents arming until acknowledged or cleared using [*][2]. 
[02] Keypad 01 – 16 RF Delinquency: No response from a wireless keypad for 13 minutes. 
[03] Siren 01 – 16 RF Delinquency: No response from a wireless siren for 13 minutes. 
[04] Repeater 01 – 16 RF Delinquency: No response from a wireless repeater for 13 minutes. 

[01] HSM2HOSTx not responding. 
[02] Keypad 01 – 16 not responding. 
[04] HSM2108 01 – 15 not responding. 
[05] HSM2300 01 – 04 not responding.
[06] HSM2204 01 – 04 not responding.
[08] HSM2208 01 – 16 not responding.
[09] HSM2955 is not responding. 
[01] HSM2HOSTx Tamper. 
[02] Keypad 01 – 16 Tamper. 
[04] HSM2108 01 – 15 Tamper. 
[05] HSM2300 01 – 04 Tamper. 
[06] HSM2204 01 – 04 Tamper. 
[08] HSM2208 01 – 16 Tamper.
[09] HSM2955 Tamper

[01] TLM: Telephone line disconnected from control panel. 
[02] Receiver 01-04 FTC Trouble: Failure to communicate using programmed receiver paths. 
[03] Alt. Comm SIM Lock: SIM card has incorrect or unrecognized PIN. 
[04] Alt. Comm Cellular: Radio or SIM card failure, low signal strength detected, or cellular network fault.
[05] Alt. Comm Ethernet: Ethernet connection unavailable. A valid IP address is either not programmed or the module was unable to get an IP with DHCP. 
[06] Receiver 01-04 Absent: Alternate communicator unable to initialize a receiver. 
[07] Receiver 01-04 Supervision: Alternate communicator unable to communicate with a receiver. 
[09] Alt. Comm Fault: The alternate communicator has stopped responding. 
[10] Alt Comm FTC Trouble: The alternate communicator has failed to communicate an internal event not generated by the panel

[01] Zone 001-128 Not Networked Trouble: Generated when a zone becomes out of sync with the wireless network or has not been synchronized with the network after enrollment. 
[02] Keypad 01-16 Not Networked Trouble: Generated when a keypad becomes out of sync with the wireless network or has not been synchronized with the network after enrollment. 
[03] Siren 01-16 Not Networked Trouble: Generated when a siren becomes out of sync with the wireless network or has not been synchronized with the network after enrollment. 
[04] Repeater 01-08 Not Networked Trouble: Generated when a repeater becomes out of sync with the wireless network or has not been synchronized with the network after enrollment. 
[05] User 01 – 1000 Not Networked Trouble: Generated when a wireless key becomes out of sync with the wireless network or has not been synchronized with the network after enrollment.