NetworX – Understanding the lights
Armed Light
The armed light is “on” when the system is armed. The armed light is “off” when it is disarmed. The armed light will flash when there has been an alarm during the previous arm cycle.
Bypass Light
The bypass light is “on” when any zone in this keypad’s partition is bypassed. The zone(s) that is bypassed will also be illuminated. If the bypass light is “off”, no zones are bypassed.
Cancel Light
The cancel light will flash during an abort delay time. If a code is entered followed by the [CANCEL] key while this light is flashing, all abortable reports will stop the communication process. Note: The abort feature must be enabled. Entering a code followed by the [CANCEL] key during or after an alarm report to the central station will cause the cancel light to come on. It will stay on until the central station has received the cancel report.
Note: The cancel feature must be enabled.
Chime Light
The chime light is “on” when the chime feature is “on”; “off” otherwise.
Exit Light
The exit light is “on” during the exit delay. Please note that the light will flash during the last 10 seconds of the exit delay as a warning that the time is running out. (The user may want to disarm the system if the exit light is flashing in order to prevent an alarm. The user may then re-arm the system and exit before the delay expires.)
Fire Light
A steady fire light means a fire zone has been faulted. A rapidly flashing fire light means that a fire zone is in a trouble condition.
Instant Light
The instant light is “on” when there is no delay on your entry/exit door(s). Any time the instant light is “on” and the exit delay has expired, the opening of an entry/exit door will produce an immediate alarm. The instant light can be toggled on or off by pressing the [Stay] key while the system is armed. When the instant light is “off”, the entry/exit door(s) is delayed.
Power Light
The power light is on if the primary power is on. The power light will flash if the system has a low battery condition.
Ready Light
The ready light is “on” when the system is ready to arm and “flashes” if ready to force arm. The ready light is off when the system is not ready to arm because of a zone(s) being faulted.
Stay Light
The stay light is “on” when the all interior (motion detector) zones are bypassed.
Zone Light
The zone lights are “off” when everything is normal. A zone light will be “on” if the zone has been bypassed. If a zone light is “flashing”, that zone is in alarm or has been faulted. If a zone light is “flashing” rapidly, it means that the zone is in a trouble condition.
Trouble conditions are:
Tamper Hardware Low Battery Loss of Supervision
(A combination of Alarm/Fault and Tamper/Trouble will produce a rapid “flashing” light for a short period of time, followed by a slow “flashing” light.)